| Technical parameter | Practical classification |
|---|---|
| Input voltage | 230 V to 690 V |
| Output voltage | 230 V to 690 V |
| Rated current | Up to 6300 A |
| Protection class | IP 20 to IP 54 |
| Protection systems | Overload protection, short-circuit protection |
| Performance | Up to 2500 kVA |
| Temperature range | -20°C to 50°C |
| Field of application | Industrial plants, office buildings |
| Economic efficiency | Low investment costs (CAPEX), medium OPEX |
| Technical parameter | Practical classification |
|---|---|
| Input voltage | 1 kV to 30 kV |
| Output voltage | 400 V to 690 V |
| Rated current | Up to 6300 A |
| Protection class | IP 33 to IP 55 |
| Protection systems | Short-circuit and overload protection |
| Performance | Up to 5000 kVA |
| Temperature range | -20°C to 50°C |
| Field of application | Energy supply, industry |
| Economic efficiency | High efficiency, medium OPEX |
| Technical parameter | Practical classification |
|---|---|
| Input voltage | 30 kV to 400 kV |
| Output voltage | 400 V to 690 V |
| Rated current | Up to 10,000 A |
| Protection class | IP 55 to IP 68 |
| Protection systems | Short-circuit and overload protection |
| Performance | Up to 50,000 kVA |
| Temperature range | -25°C to 70°C |
| Field of application | Energy supply networks, power plants |
| Economic efficiency | High investment costs, low OPEX |
| Technical parameter | Practical classification |
|---|---|
| Input voltage | 230 V to 690 V |
| Output voltage | 230 V to 690 V |
| Rated current | Up to 1500 A |
| Protection class | IP 33 to IP 54 |
| Cooling | Air cooling |
| Temperature range | -20°C to 40°C |
| Field of application | Construction sites, emergency power supply |
| Economic efficiency | High flexibility, medium OPEX |
| Technical parameter | Practical classification |
|---|---|
| Input voltage | 230 V to 690 V |
| Output voltage | 230 V to 690 V |
| Rated current | Up to 2500 A |
| Protection class | IP 65 to IP 68 |
| Protection systems | Insulated components, no dust particles |
| Temperature range | 0°C to 40°C |
| Field of application | Clean rooms, medical technology |
| Economic efficiency | High investment costs, long-term savings |
| Technical parameter | Practical classification |
|---|---|
| Input voltage | 10 kV to 30 kV |
| Output voltage | 400 V to 690 V |
| Rated power | Up to 5000 kVA |
| Design | Stationary, offshore-optimized |
| Cooling | Oil-cooled, maintenance-free |
| Protection class | IP 68, ATEX-certified |
| Temperature range | -40°C to 60°C |
| Field of application | Offshore wind farms, coastal areas |
| Economic efficiency | High investment costs, long-term savings |
| Technical parameter | Practical classification |
|---|---|
| Input voltage | 10 kV to 30 kV |
| Output voltage | 400 V to 690 V |
| Rated power | Up to 5000 kVA |
| Design | Stationary, distributed stations |
| Communication | Integrated IoT / smart grid communication |
| Efficiency | > 95 % |
| Protection class | IP 65 |
| Temperature range | -20°C to 60°C |
| Field of application | Smart grids, digital networks |
| Economic efficiency | High flexibility, high OPEX |
| Technical parameter | Practical classification |
|---|---|
| Input voltage | 10 kV to 30 kV |
| Output voltage | 400 V to 690 V |
| Rated power | Up to 5000 kVA |
| Design | Stationary, optimized for efficiency |
| Cooling | Natural cooling, low-loss |
| Power loss | < 1 % |
| Temperature range | -20°C to 60°C |
| Field of application | Energy supply companies, green projects |
| Economic efficiency | High efficiency, low OPEX |
| Technical parameter | Practical classification |
|---|---|
| Input voltage | 10 kV to 30 kV |
| Output voltage | 400 V to 690 V |
| Rated power | Up to 3000 kVA |
| Design | Stationary, distributed stations |
| Communication | Smart Load Control, IoT-capable |
| Efficiency | > 95 % |
| Protection class | IP 54 |
| Temperature range | -20°C to 50°C |
| Field of application | Industrial applications, frequency inverters |
| Economic efficiency | High flexibility, low OPEX |