| Technical parameter | Practical classification |
|---|---|
| Input voltage | 230 V to 690 V |
| Output voltage | 230 V to 690 V |
| Rated current | Up to 4000 A |
| Protection class | IP 20 to IP 54 |
| Protection systems | Overload protection, short-circuit protection |
| Technical parameter | Practical classification |
|---|---|
| Input voltage | 230 V to 690 V |
| Output voltage | 230 V to 690 V |
| Rated current | Up to 8000 A |
| Protection class | IP 33 to IP 55 |
| Protection systems | Short-circuit and overload protection |
| Performance | Up to 5000 kVA |
| Temperature range | -20°C to 60°C |
| Field of application | Large plants, industrial parks |
| Economic efficiency | High investment costs (CAPEX), medium OPEX |
| Technical parameter | Practical classification |
|---|---|
| Input voltage | 230 V to 690 V |
| Output voltage | 230 V to 690 V |
| Rated current | Up to 6000 A |
| Protection class | IP 54 |
| Protection systems | Overload protection, short-circuit protection |
| Modularity | Expandable, flexible |
| Temperature range | -20°C to 60°C |
| Field of application | Large-scale plants, energy supply networks |
| Economic efficiency | Moderate investment costs (CAPEX), low OPEX |
| Technical parameter | Practical classification |
|---|---|
| Input voltage | 230 V to 690 V |
| Output voltage | 230 V to 690 V |
| Rated current | Up to 4000 A |
| Protection class | IP 65 |
| Communication systems | IoT-capable, smart grid integration |
| Efficiency | > 95 % |
| Temperature range | -20°C to 60°C |
| Field of application | Smart grids, industrial plants |
| Economic efficiency | High flexibility, high OPEX |
| Technical parameter | Practical classification |
|---|---|
| Input voltage | 230 V to 690 V |
| Output voltage | 230 V to 690 V |
| Rated current | Up to 4000 A |
| Protection class | IP 66, ATEX-certified |
| Corrosion protection | Special materials and coatings |
| Temperature range | -40°C to 60°C |
| Field of application | Offshore, oil platforms, wind farms |
| Economic efficiency | High investment costs, long service life |
| Technical parameter | Practical classification |
|---|---|
| Input voltage | 230 V to 690 V |
| Output voltage | 230 V to 690 V |
| Rated current | Up to 5000 A |
| Protection class | IP 54 |
| Power loss | < 1 % |
| Temperature range | -20°C to 50°C |
| Field of application | Green Energy Projects, Municipal Utilities |
| Economic efficiency | High efficiency, low OPEX |
| Technical parameter | Practical classification |
|---|---|
| Input voltage | 230 V to 690 V |
| Output voltage | 230 V to 690 V |
| Rated current | Up to 4000 A |
| Protection class | IP 55, ATEX-certified |
| Hygiene standards | FDA-compliant, GMP-compliant |
| Temperature range | -20°C to 50°C |
| Field of application | Pharmaceutical industry, chemical industry |
| Economic efficiency | High investment costs, long-term savings |
| Technical parameter | Practical classification |
|---|---|
| Input voltage | 230 V to 690 V |
| Output voltage | 230 V to 690 V |
| Rated current | Up to 6300 A |
| Protection class | IP 65 |
| Redundancy | N+1, 2N Redundancy |
| Temperature range | 10°C to 30°C |
| Field of application | Data centers, IT infrastructures |
| Economic efficiency | High flexibility, high OPEX |
| Technical parameter | Practical classification |
|---|---|
| Input voltage | 230 V to 690 V |
| Output voltage | 230 V to 690 V |
| Rated current | Up to 2500 A |
| Protection class | IP 54 |
| Communication | IoT-capable, BMS-compatible |
| Temperature range | -20°C to 50°C |
| Field of application | Smart homes, building automation |
| Economic efficiency | High flexibility, low OPEX |