| Technical parameter | Practical classification |
|---|---|
| Input voltage | 10 kV to 30 kV |
| Output voltage | 400 V to 690 V |
| Rated power | Up to 1600 kVA |
| Design | Container, compact |
| Cooling | Natural cooling or air cooling |
| Protection class | IP 33 to IP 55 |
| Temperature range | -20°C to 40°C |
| Field of application | Construction sites, industrial parks |
| Economic efficiency | High flexibility, moderate OPEX |
| Technical parameter | Practical classification |
|---|---|
| Input voltage | 10 kV to 30 kV |
| Output voltage | 400 V to 690 V |
| Rated power | Up to 2500 kVA |
| Design | Stationary, free-standing |
| Cooling | Oil or air cooling |
| Protection class | IP 54 |
| Temperature range | -25°C to 60°C |
| Field of application | Public utilities, industrial plants |
| Economic efficiency | High investment costs, medium OPEX |
| Technical parameter | Practical classification |
|---|---|
| Input voltage | 30 kV to 400 kV |
| Output voltage | 400 V to 690 V |
| Rated power | Up to 10000 kVA |
| Design | Stationary, distributed stations |
| Cooling | Oil or gas cooling |
| Protection class | IP 54 to IP 67 |
| Temperature range | -25°C to 75°C |
| Field of application | Substations, power stations |
| Economic efficiency | High investment costs, low OPEX |
| Technical parameter | Practical classification |
|---|---|
| Input voltage | 10 kV to 30 kV |
| Output voltage | 400 V to 690 V |
| Rated power | Up to 1250 kVA |
| Design | Container solution, mobile |
| Cooling | Natural cooling or air cooling |
| Protection class | IP 33 to IP 54 |
| Temperature range | -20°C to 40°C |
| Field of application | Construction sites, emergency power, events |
| Economic efficiency | High flexibility, moderate OPEX |
| Technical parameter | Practical classification |
|---|---|
| Input voltage | 10 kV to 30 kV |
| Output voltage | 400 V to 690 V |
| Rated power | Up to 2500 kVA |
| Design | Stationary, ATEX-certified |
| Cooling | Oil or gas cooled |
| Protection class | IP 65 to IP 67 |
| Temperature range | -40°C to 60°C |
| Field of application | ATEX zones, oil and gas industry |
| Economic efficiency | High investment costs, long-term security |
| Technical parameter | Practical classification |
|---|---|
| Input voltage | 10 kV to 30 kV |
| Output voltage | 400 V to 690 V |
| Rated power | Up to 3000 kVA |
| Design | Stationary, free-standing |
| Cooling | Air cooling, efficient heat dissipation |
| Power loss | < 1 %/td> |
| Temperature range | -20°C to 60°C |
| Field of application | Industry, data centers, green energy projects |
| Economic efficiency | High energy efficiency, low OPEX |
| Technical parameter | Practical classification |
|---|---|
| Input voltage | 10 kV to 30 kV |
| Output voltage | 400 V to 690 V |
| Rated power | Up to 2000 kVA |
| Design | Stationary, distributed stations |
| Cooling | Oil-cooled, efficient heat dissipation |
| Load control | Integrated load management |
| Temperature range | -20°C to 60°C |
| Economic efficiency | Optimized energy efficiency |
| Technical parameter | Practical classification |
|---|---|
| Input voltage | 10 kV to 30 kV |
| Output voltage | 400 V to 690 V |
| Rated power | Up to 3000 kVA |
| Design | Stationary, distributed stations |
| Cooling | Air-cooled, efficient heat dissipation |
| Communication systems | Integration in Smart Grid / IoT |
| Temperature range | -25°C to 60°C |
| Field of application | Smart grids, digital networks |
| Economic efficiency | High flexibility, high OPEX |
| Technical parameter | Practical classification |
|---|---|
| Input voltage | 10 kV to 30 kV |
| Output voltage | 400 V to 690 V |
| Rated power | Up to 1500 kVA |
| Design | Container solution, mobile |
| Cooling | Natural cooling, efficient |
| Protection class | IP 54 to IP 65 |
| Temperature range | -20°C to 40°C |
| Field of application | Construction sites, emergency power, events |
| Economic efficiency | High flexibility, moderate OPEX |