| Technical parameter | Practical classification |
|---|---|
| Input voltage | Up to 690 V |
| Output voltage | 230 V to 690 V |
| Rated current | Up to 6300 A |
| Protection class | IP 20 to IP 54 |
| Protection systems | Overload protection, short-circuit protection |
| Performance | Up to 2500 kVA |
| Temperature range | -20°C to 50°C |
| Field of application | Industry, residential buildings, trade |
| Economic efficiency | Low investment costs (CAPEX), medium OPEX |
| Technical parameter | Practical classification |
|---|---|
| Input voltage | 10 kV to 30 kV |
| Output voltage | 400 V to 690 V |
| Rated current | Up to 5000 A |
| Protection class | IP 33 to IP 55 |
| Protection systems | Short-circuit and overload protection |
| Performance | Up to 5000 kVA |
| Temperature range | -25°C to 60°C |
| Field of application | Energy supply networks, industrial plants |
| Economic efficiency | High efficiency, medium OPEX |
| Technical parameter | Practical classification |
|---|---|
| Input voltage | 30 kV to 400 kV |
| Output voltage | 400 V to 690 V |
| Rated current | Up to 10000 A |
| Protection class | IP 54 to IP 67 |
| Protection systems | Short-circuit and overload protection |
| Performance | Up to 50,000 kVA |
| Temperature range | -25°C to 75°C |
| Field of application | Energy supply networks, power plants |
| Economic efficiency | High investment costs (CAPEX), low OPEX |
| Technical parameter | Practical classification |
|---|---|
| Input voltage | 10 kV to 30 kV |
| Output voltage | 400 V to 690 V |
| Rated current | Up to 5000 A |
| Protection class | IP 65 |
| Communication systems | Smart grid-capable (IoT, remote control) |
| Efficiency | > 95 % |
| Temperature range | -20°C to 60°C |
| Field of application | Smart grids, digital networks |
| Economic efficiency | High flexibility, medium OPEX |
| Technical parameter | Practical classification |
|---|---|
| Input voltage | 10 kV to 30 kV |
| Output voltage | 400 V to 690 V |
| Rated current | Up to 2500 A |
| Protection class | IP 65 to IP 67 |
| Hygiene standards | FDA-compliant, GMP-compliant |
| Cooling | Air-cooled or liquid-cooled |
| Temperature range | -20°C to 50°C |
| Field of application | Chemical industry, pharmaceutical industry |
| Economic efficiency | High investment costs (CAPEX), long-term savings |
| Technical parameter | Practical classification |
|---|---|
| Input voltage | 380 V to 690 V |
| Output voltage | 400 V to 690 V |
| Rated current | Up to 5000 A |
| Protection class | IP 65 to IP 68 |
| Redundancy | N+1 redundancy, 2N redundancy |
| Monitoring systems | Integrated energy monitoring software |
| Temperature range | 10°C to 35°C |
| Field of application | Data centers, IT infrastructures |
| Economic efficiency | High investment costs, medium OPEX |
| Technical parameter | Practical classification |
|---|---|
| Input voltage | 10 kV to 30 kV |
| Output voltage | 400 V to 690 V |
| Rated current | Up to 3000 A |
| Protection class | IP 65 |
| Monitoring | Integrated real-time monitoring |
| Temperature range | -20°C to 60°C |
| Field of application | Industrial plants, energy supply networks |
| Economic efficiency | High efficiency, medium OPEX |
| Technical parameter | Practical classification |
|---|---|
| Input voltage | 10 kV to 30 kV |
| Output voltage | 400 V to 690 V |
| Rated current | Up to 2500 A |
| Protection class | IP 68, ATEX-certified |
| Corrosion protection | Special coatings |
| Temperature range | -40°C to 60°C |
| Field of application | Offshore wind farms, marine environments |
| Economic efficiency | High investment costs, long service life |