| Technical parameter | Practical classification |
|---|---|
| System architecture | Central |
| Control level | PLC |
| Standard basis | IEC 61131-3 |
| Communication protocols | PROFINET, PROFIBUS |
| Real-time capability | Deterministic, cycle-dependent |
| Degree of integration | Medium |
| Scalability | Limited |
| Redundancy concept | Optional |
| Diagnostic capability | Basic to extended |
| Maintenance | System downtime required |
| Areas of application | Mechanical engineering, individual systems |
| Economic efficiency | Low CAPEX, rising OPEX with growth |
| Technical parameter | Practical classification |
|---|---|
| System architecture | Decentralized |
| Control level | PLC with remote I/O |
| Communication protocols | PROFINET, EtherCAT |
| Network topology | Line, star, ring |
| Real-time capability | High |
| Degree of integration | High |
| Scalability | Very high |
| Redundancy concept | Network redundancy possible |
| Diagnostic capability | Network-based |
| Maintenance | Possible in segments |
| Areas of application | Production lines, logistics |
| Economic efficiency | Optimized OPEX |
| Technical parameter | Practical classification |
|---|---|
| System architecture | PLC plus SCADA |
| Control level | PLC |
| Control level | SCADA |
| Communication protocols | OPC UA, TCP/IP |
| Real-time capability | Limited to visualization |
| Degree of integration | High |
| Data aggregation | Central |
| Alarm management | Integrated |
| Scalability | High |
| Maintenance | Central possible |
| Areas of application | Infrastructure, Industry |
| Economic efficiency | Moderate CAPEX |
| Technical parameter | Practical classification |
|---|---|
| System architecture | Distributed |
| Control level | DCS |
| Communication protocols | OPC UA, Industrial Ethernet |
| Real-time capability | High |
| Degree of integration | Very high |
| Redundancy concept | Integrated |
| Data archiving | Extensive |
| Visualization | Guidance system |
| Scalability | Very high |
| Maintenance | Possible during operation |
| Areas of application | Chemistry, Energy |
| Economic efficiency | High CAPEX, low OPEX |
| Technical parameter | Practical classification |
|---|---|
| System architecture | Redundant |
| CPU redundancy | Active/Standby |
| Network redundancy | Ring, PRP |
| Real-time capability | High |
| Switching time | System-dependent |
| Availability | Very high |
| Degree of integration | High |
| Diagnostic capability | Extended |
| Maintenance | Possible during operation |
| Areas of application | Energy, Pharmaceuticals |
| Project expenditure | High |
| Economic efficiency | Minimized downtimes |
| System architecture | Edge extended |
|---|---|
| Data processing | Local and central |
| Communication protocols | MQTT, OPC UA |
| Real-time capability | Partially dependent |
| Degree of integration | Very high |
| Scalability | Very high |
| Cybersecurity | Critical |
| Data analysis | Possible |
| Maintenance | Extended |
| Areas of application | Industry 4.0 |
| Project expenditure | High |
| Economic efficiency | Long-term optimization |
| Technical parameter | Practical classification |
|---|---|
| System type | Existing system |
| Degree of integration | Variable |
| Interfaces | Heterogeneous |
| Migration | Step by step |
| Risk | System-dependent |
| Documentation | Often incomplete |
| Standstill | Minimize |
| Scalability | Limited |
| Maintenance | Improvable |
| Areas of application | Industry |
| Project expenditure | High |
| Economic efficiency | Investment protection |
| Technical parameter | Practical classification |
|---|---|
| System architecture | Safety-integrated |
| Standard basis | ISO 13849, IEC 62061 |
| Security level | PL / SIL |
| Control system | Safety PLC |
| Communication protocols | PROFIsafe, FSoE |
| Degree of integration | High |
| Diagnostic capability | Safety-oriented |
| Validation | Mandatory |
| Maintenance | Restricted |
| Areas of application | Mechanical engineering, industry |
| Project expenditure | High |
| Economic efficiency | Necessary for compliance |
| Technical parameter | Practical classification |
|---|---|
| System architecture | Batch-based |
| Standard | ISA-88 |
| Control level | SPS or DCS |
| Process structure | Phases, recipes |
| Flexibility | High |
| Repeatability | High |
| Data management | Recipe management |
| Degree of integration | High |
| Scalability | Medium to high |
| Areas of application | Pharmaceuticals, Food |
| Project expenditure | Medium to high |
| Economic efficiency | Flexibility in operation |
| Technical parameter | Practical classification |
|---|---|
| System architecture | Stand-alone |
| Control level | Compact PLC |
| Degree of integration | Low |
| Interfaces | limited |
| Real-time capability | sufficient |
| Scalability | low |
| Expandability | limited |
| Diagnostic capability | Base |
| Maintenance | simple |
| Areas of application | Single machines |
| Project expenditure | low |
| Economic efficiency | Very low CAPEX |