| Technical parameter | Practical classification | |
|---|---|---|
| Input voltage | 110-400 V AC | |
| Output voltage | 24 V, 48 V, 110 V DC | |
| Rated current | Up to 1500 A | |
| Switching frequency | 50 Hz - 60 Hz | |
| Efficiency | > 90 % | |
| Power loss | < 5 % | |
| Protection class | IP 20 to IP 54 | |
| Temperature range | -20°C to 50°C | |
| Protection mechanisms | Overload, overvoltage and short-circuit protection | |
| Field of application | Mechanical engineering, small systems | |
| Economic efficiency | Low CAPEX, moderate OPEX | |
| Technical parameter | Practical classification | |
|---|---|---|
| Input voltage | 400-800 V AC | |
| Output voltage | 24 V to 1100 V DC | |
| Rated current | Up to 5000 A | |
| Switching frequency | 50 Hz - 60 Hz | |
| Efficiency | > 95 % | |
| Power loss | < 2 % | |
| Protection class | IP 20 to IP 65 | |
| Temperature range | -20°C to 60°C | |
| Protection mechanisms | Short-circuit, overload and overvoltage protection | |
| Field of application | Emergency power, high-current applications | |
| Economic efficiency | High CAPEX, low OPEX | |
| Technical parameter | Practical classification | |
|---|---|---|
| Input voltage | 380-1200 V AC | |
| Output voltage | 24 V, 48 V, 110 V DC | |
| Rated current | Up to 6000 A | |
| Switching frequency | 50 Hz - 60 Hz | |
| Efficiency | > 98 % | |
| Power loss | < 1 % | |
| Protection class | IP 55 to IP 66 | |
| Temperature range | -10°C to 60°C | |
| Redundancy | Active/Standby | |
| Field of application | Telecommunications, emergency power systems | |
| Economic efficiency | High CAPEX, low OPEX | |
| Technical parameter | Practical classification | |
|---|---|---|
| Input voltage | 380-800 V AC | |
| Output voltage | 24 V to 1100 V DC | |
| Rated current | Up to 3000 A | |
| Switching frequency | 50 Hz - 60 Hz | |
| Efficiency | > 90 % | |
| Power loss | < 3 % | |
| Protection class | IP 65 to IP 68 | |
| Temperature range | -40°C to 60°C | |
| Protection mechanisms | Corrosion-resistant housing | |
| Field of application | Offshore, extreme environments | |
| Economic efficiency | High investment costs, long-term efficiency | |
| Technical parameter | Practical classification | |
|---|---|---|
| Input voltage | 380-690 V AC | |
| Output voltage | 24 V, 48 V, 110 V DC | |
| Rated current | Up to 2000 A | |
| Switching frequency | 50 Hz - 60 Hz | |
| Efficiency | > 90 % | |
| Power loss | < 3 % | |
| Protection class | IP 65 to IP 68, ATEX-certified | |
| Temperature range | -20°C to 50°C | |
| Type of protection | Ex d, Ex e | |
| Field of application | Chemicals, pharmaceuticals, oil & gas | |
| Economic efficiency | High investment costs, long-term security | |
| Technical parameter | Practical classification | |
|---|---|---|
| Input voltage | 230-690 V AC | |
| Output voltage | 24 V, 48 V, 110 V DC | |
| Rated current | Up to 5000 A | |
| Switching frequency | 50 Hz - 60 Hz | |
| Efficiency | > 95 % | |
| Power loss | < 2 % | |
| Protection class | IP 20 to IP 65 | |
| Temperature range | -10°C to 60°C | |
| Modular design | Yes | |
| Field of application | Power distribution, emergency power | |
| Economic efficiency | High flexibility, moderate OPEX | |
| Technical parameter | Practical classification | |
|---|---|---|
| Input voltage | 230-400 V AC | |
| Output voltage | 24 V, 48 V, 110 V DC | |
| Rated current | Up to 5000 A | |
| Switching frequency | 50 Hz - 100 Hz | |
| Efficiency | > 97 % | |
| Power loss | < 1 % | |
| Protection class | IP 20 to IP 40 | |
| Temperature range | -10°C to 50°C | |
| Frequency control | Yes | |
| Field of application | Drive control, mechanical engineering | |
| Economic efficiency | High flexibility, moderate OPEX | |