| Technical parameter | Practical classification |
|---|---|
| Input voltage | 110-400 V AC |
| Output voltage | 24 V, 48 V, 110 V DC |
| Rated current | Up to 1500 A |
| Switching frequency | 50 Hz - 60 Hz |
| Efficiency | > 90 % |
| Power loss | < 5 % |
| Protection class | IP 20 to IP 54 |
| Temperature range | -20°C to 50°C |
| Protection mechanisms | Overload, overvoltage and short-circuit protection |
| Field of application | Mechanical engineering, small systems |
| Economic efficiency | Low CAPEX, moderate OPEX |
| Technical parameter | Practical classification |
|---|---|
| Input voltage | 400-800 V AC |
| Output voltage | 24 V to 1100 V DC |
| Rated current | Up to 5000 A |
| Switching frequency | 50 Hz - 60 Hz |
| Efficiency | > 95 % |
| Power loss | < 2 % |
| Protection class | IP 20 to IP 65 |
| Temperature range | -20°C to 60°C |
| Protection mechanisms | Short-circuit, overload and overvoltage protection |
| Field of application | Emergency power, high-current applications |
| Economic efficiency | High CAPEX, low OPEX |
| Technical parameter | Practical classification |
|---|---|
| Input voltage | 230 V AC, 400 V AC |
| Output voltage | 24 V, 48 V DC |
| Rated current | Up to 500 A |
| Switching frequency | 50 kHz - 100 kHz |
| Efficiency | > 95 % |
| Power loss | < 2 % |
| Protection class | IP 20 to IP 40 |
| Temperature range | -10°C to 50°C |
| Areas of application | Drives, controls |
| Economic efficiency | High efficiency, low OPEX |
| Technical parameter | Practical classification |
|---|---|
| Input voltage | 480-1200 V AC |
| Output voltage | 24 V, 48 V, 110 V DC |
| Rated current | Up to 6000 A |
| Switching frequency | 50 Hz - 60 Hz |
| Efficiency | > 98 % |
| Power loss | < 1 % |
| Protection class | IP 55 to IP 66 |
| Temperature range | -10°C to 60°C |
| Redundancy | Active/Standby |
| Field of application | Telecommunications, emergency power systems |
| Economic efficiency | High CAPEX, low OPEX |
| Technical parameter | Practical classification |
|---|---|
| Input voltage | 380-690 V AC |
| Output voltage | 24 V, 48 V, 110 V DC |
| Rated current | Up to 2000 A |
| Switching frequency | 50 Hz - 60 Hz |
| Efficiency | > 90 % |
| Power loss | < 3 % |
| Protection class | IP 65 to IP 68, ATEX-certified |
| Temperature range | -20°C to 50°C |
| Type of protection | Ex d, Ex e |
| Field of application | Chemicals, pharmaceuticals, oil & gas |
| Economic efficiency | High investment costs, long-term security |
| Technical parameter | Practical classification |
| Input voltage | 110-400 V AC |
| Output voltage | 24 V, 48 V, 110 V DC |
| Rated current | Up to 1500 A |
| Switching frequency | 50 Hz - 60 Hz |
| Efficiency | > 90 % |
| Power loss | < 5 % |
| Protection class | IP 44 to IP 54 |
| Temperature range | -20°C to 50°C |
| Protection mechanisms | Overload protection, IP protection |
| Field of application | Mobile construction sites, emergency supply |
| Economic efficiency | Low CAPEX, high flexibility |
| Technical parameter | Practical classification |
|---|---|
| Input voltage | 110-400 V AC |
| Output voltage | 24 V, 48 V, 110 V DC |
| Rated current | Up to 1500 A |
| Switching frequency | 50 Hz - 60 Hz |
| Efficiency | > 90 % |
| Power loss | < 5 % |
| Protection class | IP 20 to IP 54 |
| Temperature range | -20°C to 50°C |
| Protection mechanisms | Overload, overvoltage and short-circuit protection |
| Field of application | Mechanical engineering, small systems |
| Economic efficiency | Low CAPEX, moderate OPEX |